CLICK PLC Overview


Download CLICK PLC Overview


Preview text

CLICK PLC Overview

CPU Modules
The eleven CLICK CPU modules are available with different combinations of built-in I/O types.

Basic CPU

Part Number
C0-00DD1-D C0-00DD2-D C0-00DR-D C0-00AR-D

CLICK Basic CPU Modules

Inputs (8 points)

Outputs (6 points)

DC (0.1 A, 5-24 VDC, Sink)

DC (24 VDC, sink/source)

DC (0.1 A, 24 VDC, Source)

AC (100-120 VAC)

Relay (1 [email protected] VDC/6-240 VAC)

Basic CPU Module Features: • Eight discrete input points • Six discrete output points • Two RS-232 communications ports

Price
<---> <---> <---> <--->

Standard CPU

Part Number
C0-01DD1-D C0-01DD2-D C0-01DR-D C0-01AR-D

CLICK Standard CPU Modules

Inputs (8 points)

Outputs (6 points)

DC (24 VDC, sink/source)

DC (0.1 A, 5-24 VDC, Sink) DC (0.1 A, 24 VDC, Source)

AC (100-120 VAC)

Relay (1 [email protected] VDC/6-240 VAC)

Standard CPU Module Features: • Eight discrete input points • Six discrete output points • Two RS-232 communications ports • One RS-485 communications port • Backup battery (Battery sold separately)

Price
<---> <---> <---> <--->

Analog CPU

Volume 13
e1-16

Programmable Controllers

Part Number
C0-02DD1-D C0-02DD2-D C0-02DR-D

CLICK Analog CPU Modules

Inputs (4 points)

Outputs (4 points)

Analog Inputs, Outputs

DC (24 VDC, sink/source)

DC (0.1 A, 5-24 VDC, Sink) DC (0.1 A, 24 VDC, Source) Relay (1 [email protected] VDC/6-240 VAC)

2 channels in / 2 channels out; voltage (0-5 VDC) and current (4-20 mA) selectable

Price
<---> <---> <--->

Analog CPU Module Features: • Four discrete input points and four discrete output points • Two analog input points and two analog output points • Two RS-232 communications ports • One RS-485 communications port • Backup battery (Battery sold separately)

1 - 8 0 0 - 633 - 0 4 05

CLICK PLC Overview
Input I/O Modules
There are six input I/O modules available.

C0-08ND3

C0-08ND3-1

C0-16ND3

CLICK Input I/O Modules

Part Number

Inputs

C0-08ND3

DC (8 pts, 12-27 VDC)

C0-08ND3-1

DC (8 pts, 3.3-5 VDC)

C0-16ND3

DC (16 pts, 24 VDC)

C0-08NE3

AC/DC (8 pts, 24 VAC/VDC)

C0-16NE3

AC/DC (16 pts, 24 VAC/VDC)

C0-08NA

AC (8 pts, 100-120 VAC)

Price
<---> <---> <---> <---> <---> <--->

C0-08NE3

C0-16NE3

Output I/O Modules
There are seven output I/O modules available.

C0-08NA

C0-08TD1

C0-08TD2

C0-16TD1

CLICK Output I/O Modules

Part Number

Outputs

C0-08TD1

DC (8 pts, 0.3 A @ 3.3-27 VDC, Sink)

C0-08TD2

DC (8 pts, 0.3 A @ 12-24 VDC, Source)

C0-16TD1

DC (16 pts, 0.1 A @ 5-27 VDC, Sink)

C0-16TD2

DC (16 pts, 0.1 A @ 12-24 VDC, Source)

C0-08TA

AC (8 pts, 0.3A @ 17-240 VAC)

C0-04TRS* Relay (4 pts, 7A @ 6-27 VDC/6-240 VAC)

C0-08TR

Relay (8 pts, 1A @ 6-27 VDC/6-240 VAC)

Price
<---> <---> <---> <---> <---> <---> <--->

* To drive more than a 7A load or to use replaceable relays, consider using a C0-16TD1 output module with a ZL-RRL16-24 ZIPLink relay module and the correct ZIPLink cable (see Wiring System for CLICK PLCs later in this section).

C0-16TD2

C0-08TA

Power Supplies
Two power supplies are offered.

C0-04TRS

C0-08TR

Part Number
C0-00AC C0-01AC

CLICK Power Supplies

Input Voltage

Output Current

85-264 VAC 0.5A @ 24 VDC

85-264 VAC 1.3A @ 24 VDC

Price
<---> <--->

C0-00AC

C0-01AC

w w w. a u t o m a t i o n d i r e c t . c o m / c l i c k- p l c

Programmable Controllers

Volume 13
e1-17

Company Information
Systems Overview
Programmable Controllers
Field I/O
Software
C-more & other HMI
Drives
Soft Starters
Motors & Gearbox
Steppers/ Servos
Motor Controls
Proximity Sensors
Photo Sensors
Limit Switches
Encoders
Current Sensors
Pressure Sensors
Temperature Sensors
Pushbuttons/ Lights
Process
Relays/ Timers
Comm.
Terminal Blocks & Wiring
Power
Circuit Protection
Enclosures
Tools
Pneumatics
Appendix
Product Index
Part # Index

CLICK PLC Overview

What you’ll need
Of course, what you’ll need for your system depends on your particular application, but this overview shows you what you’ll need for a simple system.

1. Select your CLICK CPU module.

2. If you need additional I/O, select from thirteen types of I/O modules.

3. Select a 24 VDC power supply.

or

4. Download the FREE CLICK programming software.

5. Select your PC-to-PLC programming cable.
If your PC has a USB port, use cable EA-MG-PGM-CBL to connect to the CPU module port. If your PC has a 9-pin serial communications port, use programming cable D2-DSCBL.

EA-MG-PGM-CBL
or

D2-DSCBL

6. Select tools, wire, and provide power.

Screwdriver DN-SS1

Wire Strippers DN-WS

Hookup Wire

(PC requires RS-232 port to use this cable)

Volume 13
e1-18

Programmable Controllers

1 - 8 0 0 - 633 - 0 4 05

CLICK Programming Software

Company Information

Systems Overview

FREE Software!
CLICK programming software can be downloaded at no charge.
The CLICK programming software is designed to be a user-friendly application, and the tools, layout, and software interaction provide ease-of-use and quick learning.
The simple operation of this software allows users to quickly develop a ladder logic program. The online help file provides information that will help you get acquainted with the software quickly.
PC Requirements
CLICK PLC Windows-based programming software works with Windows® 2000 Service Pack 4, XP Home or Professional, Vista (32 bit only) or Windows 7 (32 bit only). These are the minimum system requirements:
• Personal Computer with a 333 MHz or higher processor (CPU) clock speed recommended; Intel Pentium/Celeron family or AMD K6/Athlon/Duron family, or compatible processor recommended
• SVGA 800x600 pixels resolution. (1024x768 pixels resolution recommended)
• 150MB free hard-disk space
• 128MB free Ram (512MB recommended)
• CD-ROM or DVD drive for installing software from the CD
• 9-pin serial port or USB port for project transfer to PLC (USB port communications also requires USB-to-serial converter)
C0-PGMSW FREE
CLICK PLC Programming Software
Free download available from the Web includes the manual in pdf format. Cable sold separately.
Windows2000/XP(Home/Pro)/Vista/ Windows 7 required.
The CLICK Programming Software can be downloaded free at the AutomationDirect Web site:
www.support.automationdirect.com/ downloads.html

NOTE: CLICK PLCs cannot be programmed using Direct SOFT5 programming software, which is used to program our Direct LOGIC PLCs; you must use the CLICK programming software, C0-PGMSW.

Programmable Controllers
Field I/O

Software

NOTE: When using Standard CPUs, you must use CLICK programming software version V1.20 or later. When using Analog CPUs, you must use CLICK programming software version V1.12 or later.

C-more & other HMI
Drives
Soft Starters

Motors & Gearbox

Steppers/ Servos

Main window
The Main Window is displayed when the program opens. It is divided into Menus, Toolbars, and Windows that work together to make project development as simple as possible.

Motor Controls
Proximity Sensors
Photo Sensors
Limit Switches

Encoders

Current Sensors

Pressure Sensors

Temperature Sensors

Pushbuttons/ Lights

Process

Relays/ Timers

Comm.

Terminal Blocks & Wiring

Power

Navigation Window

Ladder Edit Window

Instruction List Window

Circuit Protection
Enclosures
Tools

Pneumatics

Appendix

Product Index

Part # Index

w w w. a u t o m a t i o n d i r e c t . c o m / c l i c k- p l c

Programmable Controllers

Volume 13
e1-19

CLICK Programming Software

Instructions
The easy-to-use instructions are described in the CLICK programming software online help file.
Powerful Features!
CLICK programming software has amazingly powerful features for a free software product, such as
• Address picker • Separate subroutine programs • Separate interrupt programs • Color rung comment feature • Project loader • Documentation is stored within the PLC memory

Address Picker
The Address Picker is a powerful multi-function memory table which can be used to assign nicknames, create address comments, and establish initial values for specific memory locations. It can assign specific memory locations to be retentive during power outages. The Address Picker also has powerful tools for sorting the memory table and making it easier to use.

Subroutine Programs
Subroutine programs can be created and named to isolate a body of program code that is run selectively. You can run up to 986 subroutine programs.
Interrupt Programs
Interrupt programs are created and named. The Basic and Standard CPU modules support up to 12 interrupt programs. The Analog CPU modules support up to 8 interrupt programs.

Volume 13
e1-20

Programmable Controllers

1 - 8 0 0 - 633 - 0 4 05

CLICK Programming Software
Color Rung Comment
Easily create and edit rung comments with colors and three text styles. Comments are stored in the PLC memory for future reference.
Project Loader
The CLICK programming software can export the CLICK project in an encrypted format. The exported file can be sent to the end user. Then the end user can download the file into the CLICK PLC with the tool called Project Loader.

NOTE: PROJECT LOADER IS A SEPARATE PROGRAM FROM THE CLICK PROGRAMMING SOFTWARE, BUT IT IS INSTALLED ON THE PC WHEN THE CLICK PROGRAMMING SOFTWARE IS INSTALLED.

w w w. a u t o m a t i o n d i r e c t . c o m / c l i c k- p l c

Programmable Controllers

Volume 13
e1-21

Company Information
Systems Overview
Programmable Controllers
Field I/O
Software
C-more & other HMI
Drives
Soft Starters
Motors & Gearbox
Steppers/ Servos
Motor Controls
Proximity Sensors
Photo Sensors
Limit Switches
Encoders
Current Sensors
Pressure Sensors
Temperature Sensors
Pushbuttons/ Lights
Process
Relays/ Timers
Comm.
Terminal Blocks & Wiring
Power
Circuit Protection
Enclosures
Tools
Pneumatics
Appendix
Product Index
Part # Index

Product Dimensions and Installation

It is important to understand the installation requirements for your CLICK system. Your knowledge of these requirements will help ensure that your system operates within its environmental and electrical limits.
Plan for Safety
This catalog should never be used as a replacement for the user manual.
You can purchase, download free, or view online the user manuals for these products. Manual C0-USER-M is the user manual for the CLICK PLC. This user manual contains important safety information that must be followed. The system installation should comply with all appropriate electrical codes and standards.

Panel

Ground Braid Copper Lugs

Panel or Single Point
Ground

Star Washers Star Washers

2 in. 50.8 mm minimum
2 in. 50.8mm minimum
3 in. 76.2 mm minimum

NOTE: THERE IS A MIMIMUM CLEARANCE REQUIREMENT OF 2 INCHES(51 MM) BETWEEN THE CLICK PLC AND THE PANEL DOOR OR ANY DEVICES MOUNTED IN THE PANEL DOOR. THE SAME CLEARANCE IS REQUIRED BETWEEN THE PLC AND ANY SIDE OF THE ENCLOSURE. A MINIMUM CLEARANCE OF 3 INCHES (76 MM) IS REQUIRED BETWEEN THE PLC AND A WIREWAY OR ANY HEAT PRODUCING DEVICE.

Mounting Orientation
CLICK PLCs must be mounted properly to ensure ample airflow for cooling purposes. It is important to follow the unit orientation requirements and to verify that the PLC’s dimensions are compatible with your application. Notice particularly the grounding requirements and the recommended cabinet clearances.

Air Flow

Volume 13
e1-22

Programmable Controllers

1 - 8 0 0 - 633 - 0 4 05

PWR

RUN

RUN

ERR

STOP

PORT1 TX1 RX1

TX2 RX2 PORT2

Product Dimensions and Installation

Latch tabs

Connecting the Modules Together
CLICK CPUs, I/O modules and power supplies connect together using the extension ports that are located on the side panels of the modules (no PLC backplane/base required).
1. Remove extension port covers and slide the latch tabs forward.
2. Align the module pins and connection plug, and press the I/O module onto the right side of the CPU.
3. Slide the latch tabs backward to lock the modules together.

3
Connecting Modules
2
1

Supports up to eight I/O modules

Mounting
The CLICK PLC system, which includes the CLICK power supplies, CPU modules, and I/O modules, can be mounted in one of two ways.
1. DIN rail mounted
2. Surface mounted using the built-in upper and lower mounting tabs.

DIN Rail Mounting

Surface Mounting
Upper Mounting Tab

Pull tab down.

Push tab up until...

Click

Lower Mounting Tab

Unit Dimensions
These diagrams show the outside dimensions of the CLICK power suppy, CPU, and I/O modules. The CLICK PLC system is designed to be mounted on standard 35mm DIN rail, or it can be surface mounted.
Allow proper spacing from other components within an enclosure.
Maximum system:
Power Supply + CPU + 8 I/O modules.

0.102 [2.6]
3.35 [85]
0.16 [4]

Power Supply Module
1.37 [34.9]

CPU Module
2.11 [53.5]
"

0.36 [9.2]

I/O Module

1.06

0.46

[27]

[13.5]

2.95

[75]

0.37 [9.4]
Dimensions in inches [millimeters]

Company Information
Systems Overview
Programmable Controllers
Field I/O
Software
C-more & other HMI
Drives
Soft Starters
Motors & Gearbox
Steppers/ Servos
Motor Controls
Proximity Sensors
Photo Sensors
Limit Switches
Encoders
Current Sensors
Pressure Sensors
Temperature Sensors
Pushbuttons/ Lights
Process
Relays/ Timers
Comm.
Terminal Blocks & Wiring
Power
Circuit Protection
Enclosures
Tools
Pneumatics
Appendix
Product Index
Part # Index

w w w. a u t o m a t i o n d i r e c t . c o m / c l i c k- p l c

Programmable Controllers

Volume 13
e1-23

Product Dimensions and Installation

Unit Dimensions Power Supply

1.37

0.10

0.53

[34.9]

[2.6]

[13.5]

2.95

[75]
*

CLICK POWER SUPPLY

3.64 [92.4]

OUTPUT 24V 0.5A
24V
0V
G
L
N
INPUT 100-240V 15VA 50-60Hz

8 5

3.35 [85]

CPU Module
0.10 [2.6]

*

0.16

Dimensions in inches [millimeters]

[4]

* Use size M4 screws for top and bottom mounting tab holes.

0.19 0.37

[4.8]

2.11

[53.5]

[9.4]

2.95

0.2

[75]

*

[5]

3.35 [85]

CLICK CPU MODULE

PWR

RUN

RUN

ERR

STOP

PORT1
TX1 RX1

TX2 RX2
PORT2

3.66 [93]

I/O Module

0.36 [9.2]
0.33 [8.5]

* Use size M4 screws for top and bottom mounting tab holes.

1.06 [27]
*

0.10

0.37

[2.6]

[9.4]

Dimensions in inches [millimeters]
2.95 [75]

CLICK I/O MODULE

3.64

3.35

[92.4]

[85]

Volume 13
e1-24

Programmable Controllers

*

0.16

Dimensions in inches [millimeters]

[4]

* Use size M4 screws for top and bottom mounting tab holes.

1 - 8 0 0 - 633 - 0 4 05

Networking the CLICK PLC

Company Information

Systems Overview

Built-in Communications Ports
All CPUs have two built-in RS-232 communications ports. Standard and Analog CPUs also have one built-in RS-485 communications port. One RS-232 port supports the Modbus RTU protocol only and can be used as the programming port. The other ports support either Modbus RTU or ASCII protocol. Both RS-232 ports supply 5 VDC, so you can connect a monochrome C-more Micro HMI panel without an additional power supply.
LED Status Indicators
There are LED indicators located to the left of each communication port to indicate when the port is transmitting or receiving.

Com Port 1

Com Port 2

Basic CPU

Com Port 1 Specifications
Use: Programming Port Physical: 6 pin, RJ12, RS-232 Communication speed (baud): 38400 (fixed) Parity: Odd Station Address: 1 Data length: 8 bits Stop bit: 1 Protocol: Modbus RTU (slave only)

Com Port 1
Com Port 2 Com Port 3
Standard and Analog CPUs

Port 1
6 pin RJ12 Phone Type Jack

6

1

Port 1 Pin Descriptions
1 0V Power (-) connection (GND) 2 5V Power (+) connection 3 RXD Receive data (RS-232) 4 TXD Transmit data (RS-232) 5 NC No connection 6 0V Power (-) connection (GND)

Basic CPUs

Port 1 & 2 LED Status Indicators

TX1 and TX2 (Green) On The Comm Port is sending data. Off The Comm Port is not sending data.

PORT1 TX1 RX1

STOP

RX1 and RX2 (Green) On The Comm Port is receiving data. Off The Comm Port is not receiving data.

TX2 RX2 PORT2

Standard and Analog CPUs

Port 1, 2, & 3 LED Status Indicators
RUN
ERR

TX1, TX2 and TX3 (Green) On The Comm Port is sending data. Off The Comm Port is not sending data.
RX1, RX2 and RX3 (Green) On The Comm Port is receiving data. Off The Comm Port is not receiving data.

PORT1 TX1 RX1

TX2 RX2 PORT2

PORT3
TX3 RX3

RS-485

Com Port 2 Specifications
Use: Serial Communication Physical: 6 pin, RJ12, RS-232 Communication speed (baud): 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Parity: odd, even, none Station Address: 1 to 247 Data length: 8 bits (Modbus RTU) or 7, 8 bits (ASCII) Stop bit: 1,2 Protocol: Modbus RTU (master/slave) or ASCII in/out

Port 2
6 pin RJ12 Phone Type Jack

6

1

Com Port 3 Specifications
Use: Serial Communication Physical: 3 pin, RS-485 Communication speed (baud): 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Parity: odd, even, none Station Address: 1 to 247 Data length: 8 bits (Modbus RTU) or 7, 8 bits ( ASCII) Stop bit: 1,2 Protocol: Modbus RTU (master/slave) or ASCII in/out

Port 3 RS-485

Port 2 Pin Descriptions
1 0V Power (-) connection (GND) 2 5V Power (+) connection 3 RXD Receive data (RS-232) 4 TXD Transmit data (RS-232) 5 RTS Request to send 6 0V Power (-) connection (GND)

Port 3 Pin Descriptions
1 + (plus) Signal A (RS-485)

2 - (minus) Signal B (RS-485)

3

LG

Logic Ground(0 V)

Programmable Controllers
Field I/O
Software
C-more & other HMI
Drives
Soft Starters
Motors & Gearbox
Steppers/ Servos
Motor Controls
Proximity Sensors
Photo Sensors
Limit Switches
Encoders
Current Sensors
Pressure Sensors
Temperature Sensors
Pushbuttons/ Lights
Process
Relays/ Timers
Comm.
Terminal Blocks & Wiring
Power
Circuit Protection

Port Setup
Use CLICK programming software to easily configure the communication ports.

Enclosures Tools Pneumatics Appendix

Product Index

Part # Index

w w w. a u t o m a t i o n d i r e c t . c o m / c l i c k- p l c

Programmable Controllers

Volume 13
e1-25

Preparing to load PDF file. please wait...

0 of 0
100%
CLICK PLC Overview