USE: Reference list APPROVED METERING AND SERVICE EQUIPMENT


Download USE: Reference list APPROVED METERING AND SERVICE EQUIPMENT


Preview text

USE: Reference list to purchase or stock approved metering service equipment

APPROVED METERING AND SERVICE EQUIPMENT Guidelines for Metering Equipment

Note: This list is of approved manufacturer's meter sockets is indicative of many types of equipment that is acceptable but is not an exhaustive list of all possible acceptable versions manufactured by a particular company. The general guidelines for selecting meter equipment are:
Oto 200 amp single and three phase services for Self-Contained meter enclosures (meter sockets only, all in ones, multi-packs and pedestals,): • Classified as EUSERC, UL and ANSI approved metering equipment • AIC rating of 10,000 amps or greater • "A" base or "K" base meter sockets are not approved (bar type/ bolted in meters are not allowed) • All sockets will be ring types (ringless sockets not allowed) • Dual rated enclosure for Overhead and Underground usage are required, except as noted • All non-residential services shall have manual means of bypassing (not applicable for non-occupied
services) so businesses will not be affected when maintenance is performed. • Manual link bypasses (lever bypasses and automatic bypasses not allowed) • Safety Sockets will be utilized on any 480 volt services • Breakers used as main disconnecting devices rather than fuses when fault interrupting capabilities are in
compliance. • Fused equipment approved on a case by case basis for retrofits or where a main breaker disconnects
fault interrupting ratings would be exceeded. • Multi-pack equipment with more than 4 sockets in height will not be accepted.
201 to 400 amp single and three phase services for Self-Contained meter enclosures (meter sockets only, all in ones, multi-packs, and pedestals,): • Classified as EUSERC, UL and ANSI approved metering equipment • AIC rating of 22,000 amps or greater • "A" base or "K" base meter sockets are not approved (bar type meter are not allowed) • All sockets will be ring types (ringless sockets not allowed) • Dual rated enclosure for Overhead and Underground usage are required, except as noted • All non-residential services shall have manual means of bypassing so businesses will not be affected
when maintenance is performed • Manual link bypasses (lever bypasses and automatic bypasses not allowed) • 400 amp self-contained meter socket with manual link bypasses for single-phase only • Safety Sockets will be utilized on any 480 volt services • Breakers used as main disconnecting devices rather than fuses when fault interrupting capabilities are in
compliance. • Fused equipment approved on a case by case basis for retrofits or where a main breaker disconnects
fault interrupting ratings would be exceeded. • Multi-pack equipment with more than 4 sockets in height will not be accepted.
For approval of equipment not included in the approved list, contact Tucson Electric Power at (520) 918-8280. A factory representative shall provide product information and data sheets and a product sample for TEP in house review and approval. TEP will update and electronically publish the approved list on a quarterly basis during the months of January, April, July and October. It will be the responsibility of each panel manufacturer to notify TEP of any change of catalog number, specifications or if the panel is no longer available.

UniSouroeEnergy .......-...._

INITIATED BY

GC REVISION NO.

9

1------+---_:--------+-----1

SR-452

Tucson Electric Power

SERVIES SMTACRUZCDUNn ESR COMM.

ESR COMM. 10-06 EFFECTIVE DATE

4-18 4-18

Pg. 1 of 14

-I
C
C")
i iUI
0
i"ti
...

! i)- = nMP'PI

-=1=... !E;= m
en

..... :...z..

~
n
0

.-..I..
~

3: m

3: 0

-O
....

0 I
0

n 0

°'

9 m
"Tl
"mTl

m en
~

~
.~....

n en

<

0 3:

8
:z

m 3: :z

0
~

0

m

.... .... .... .SI, .SI,

I

I

.SI,
00 00

.-a u,
ID :;:a I
N .,:a.
...0 UI
.... N
.,:a.

USE: Reference list to purchase or stock approved metering service equipment

TEP SR# SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408

Type of Application All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One

APPROVED METERING AND SERVICE EQUIPMENT

Size

Manufacturer

100 Eaton Cutler-Hammer

100 Eaton Cutler-Hammer

100 Eaton Cutler-Hammer

100 Eaton Cutler-Hammer

100 Eaton Cutler-Hammer

100

GE

100

Siemens

100

Siemens

100

Siemens

100

Siemens

100

Siemens

100

Square D

100

Square D

100

Square D

100

Square D

125 Eaton Cutler-Hammer

125 Eaton Cutler-Hammer

125 Eaton Cutler-Hammer

125 Eaton Cutler-Hammer

125 Eaton Cutler-Hammer

125 Eaton Cutler-Hammer

125

GE

125

Murray

125

Siemens

125

Siemens

125

Siemens

125

Siemens

125

Square D

125

Square D

150

Square D

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

Catalog Number MBE1224B100BTF MBE1224B100BTS MBE1224B100TS MBE1224PV100BTF MBE1224PV100BTS
TSM1610CSCU MC1020B1100SZ MC1224B1100EFC MC1224B1100ESC MC1224B1100FEC MC1224B1100SEC
SC1624MlOOF SC1624MlOOS S01020MlOOS S01020M100VP CMBE2222B125BF CMBE2222B125BS MBE1224B125BTF MBE1224B125BTS MBE1224PV125BTF MBE1224PV125BTS TSM1212CSCU JA1632B1125SEC MC1224B1125EFC MC1224B1125ESC MC1224B1125FEC MC1224B1125SEC SC1624M125F SC1624M125S SC816F150PS CMBE1212L200BF CMBE1212L200BS

Phase 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Fault Rating 10 10 10 10 10 22 22 22 22 22 22 10 10 10 10 10 10 10 10 10 10 22 22 22 22 22 22 10 10 22 10/22 10/22

OH UG X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

Terminals 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

, Test - Bypass Equipped
+ The Cat. Number is out of date & will be removed the following
year to allow stock out.

n The panel requires a HP40TFKIT kit to be purchased if this panel is to be
served from overhead.
"" New addition to the book.

-I
C
C")
i iUI
0
i"ti
...

! i)- = nMP'PI

-=1=... !E;= m
en

..... :...z..

~
n
0

.-..I..
~

3: m

3: 0

-O
....

0 I
0

n 0

°'

9 m
"Tl
"mTl

m en
~

~
.~....

n en

<

0 3:

8
:z

m 3: :z

0
~

0

m

.... .... .... .SI, .SI,

I

I

.SI,
00 00

.-a u,

ID :;:a

w

I
.,:a.

...0 UI
.... N
.,:a.

USE: Reference list to purchase or stock approved metering service equipment

TEP SR# SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408

Type of Application All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One

APPROVED METERING AND SERVICE EQUIPMENT

Size

Manufacturer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200

GE

200

GE

200

GE

200

GE

200

GE

200

GE

200

Murray

200

Murray

200

Murray

Catalog Number CMBE1212L200TS CMBE24B200TSR CMBE4242B200BS2 CMBE4242B200BTF CMBE4242B200BTS CMBE4242B200TS CMBE4242PV200BS CMBE4242PV200TS CMBE88B200BTF CMBE88B200BTS HP404040SH-PV HP404040SHA-PV ¥ MBE1212L200BF MBE1212L200BS MBE2040B200BTS MBE2040B200TS MBE2040PV200BTF MBE2040PV200BTS MBE4040B200BTF MBE4040B200BTS MBE4040B200TS MBE4040PV200BTF MBE4040PV200BTS MBE88B200BTF MBE88B200BTS
TSM2020CSCU TSM2420UF42 TSM2420US42 TSM3220UFCU TSM3220UWCU TSM4020UWCU JA1212L1200FED JA1212L1200SED JC0406L1200H

Phase 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Fault Rating 10/22 35 35 22 22 35 22 22 22 22 10/25 10/25 10/22 10/22 10 10 22 22 22 22 10 22 22 10/22 10/22 22 22 22 22 22 22 22 22 22

OH UG X X
X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

Terminals 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

, Test - Bypass Equipped
+ The Cat. Number is out of date & will be removed the following
year to allow stock out.

n The panel requires a HP40TFKIT kit to be purchased if this panel is to be
served from overhead.
"" New addition to the book.

-I
C
C")
i iUI
0
i"ti
...

! i)- = nMP'PI

-=1=... !E;= emn

..... :...z..

~
n
0

.-..I..
~

3: m

3: 0

O-
....

0 I
0

n 0

°'

9 m
"Tl
"mTl

em n
~

~
.~....

n en

<

0 3:

8
:z

m 3: :z

0
~

0

m

°' .....SI, I

.....SI, I

....

00 00

.-a u,
ID :;:a I
.,l:li, .,l:li,
...0 UI
.... N
.,l:li,

USE: Reference list to purchase or stock approved metering service equipment

TEP SR# SR-408 SR-408
SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408

Type of Application All-In-One All-In-One
All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One

APPROVED METERING AND SERVICE EQUIPMENT

Size

Manufacturer

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Siemens

200

Square D

200

Siemens

200

Square D

200

Square D

200

Square D

200

Square D

200

Square D

200

Square D

200

Square D

200

Square D

200

Square D

Catalog Number MC0816B1200EST
MC0816B1200T .fa MC0816S1200SCT MC1212L1200FED MC1212L1200SED MC2040B1200EFC MC2040B1200ESC MC2040B1200F MC2040B1200FED MC2040B1200S MC2040B1200SED MC2040B1200SZ MC2442B1200EFC MC2442B1200ESC MC2442B1200ESV MC2442B1200FEC MC2442B1200SEC MC2442S1200FC MC2442S1200SC MC3040B1200SECW MC3040S1200SC MC3042B1200FED MC3042B1200SED MC4040B1200SECW MC4040S1200SC
SC2040M200C SC2040M200F SC2040M200PS SC2040M200S SC3040M200F SC3040M200S SC3042M200PS SC40M200S SC40M200SA250LH

Phase 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Fault Rating 22
22
22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 10 22 22 22 22 22 22 22 22

OH UG
X X
X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

Terminals 4
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

, Test - Bypass Equipped
+ The Cat. Number is out of date & will be removed the following
year to allow stock out.

n The panel requires a HP40TFKIT kit to be purchased if this panel is to be
served from overhead.
.fa New addition to the book.

-I
C
C")
i iUI
0
i"ti
...

! i)- = nMP'PI

-=1=... !E;= m
en

..... :...z..

~
n
0

.-..I..
~

3: m

3: 0

-O
....

0 I
0

n 0

°'

9 m
"Tl
"mTl

m en
~

~
.~....

n en

<

0 3:

8
:z

m 3: :z

0
~

0

m

°' .....SI, I

.....SI, I

....

00 00

.-a u,
ID :;:a I
UI .,:a.
...0 UI
.... N
.,:a.

USE: Reference list to purchase or stock approved metering service equipment

TEP SR# SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412
SR-412 SR-412
SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412

Type of Application All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One
All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One All-In-One

APPROVED METERING AND SERVICE EQUIPMENT

Size

Manufacturer

200

Square D

200

Square D

200

Square D

200

Square D

200

Square D

200

Siemens

250

Siemens

300

Eaton Cutler-Hammer

300

Siemens

320

Milbank

320

Milbank

400

Eaton Cutler-Hammer

400

Eaton Cutler-Hammer

400

Eaton Cutler-Hammer

400

Eaton Cutler-Hammer

400

Eaton Cutler-Hammer

400

Eaton Cutler-Hammer

400

Eaton Cutler-Hammer

400

Eaton Cutler-Hammer

400

Eaton Cutler-Hammer

400

Eaton Cutler-Hammer

400

Eaton Cutler-Hammer

400

GE

400

GE

400

Murray

400

Murray

400

Murray

400

Siemens

400

Siemens

400

Siemens

400

Siemens

400

Siemens

400

Siemens

Catalog Number SC42M200PS SC816F200PS S02040M200S
S02040M200VP SU3040M200R MC2040S1200SZ MC0816B1200ESN HP304040SH .rJ MC3040MB21
M400-APS U3251-0-200-CB CG1212P400BS CG403242SH .rJ
CG40SH .rJ H816P400BS .rJ H816P400BS(HPPR) .rJ
HP40 .rJ HP40(HPPR) .rJ
HP402442 .rJ HP404040SH .rJ HP404040SHA .rJ ,
HP40SH .rJ TMH2440RMS T5DA2440UC42 JA0816B1400SCS , JA3042B1400SCS , JC0404L1400SCS , MC2442B1400SD , MC3040MB22 MC3042B1400FD MC3042B1400SD MC3042B1200SPV MC3042S1400SC ,

Phase 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Fault Rating 22 22 22 22 10 22 22 22 22 10 10 22 22 22
10/22
10/22 10/22 10/22
10/22 10/22 10/22 10/22
22 22 22 10 22 22 22 22 22 22 22

OH UG X X X X X X
X X X X
X X X X X X X X X
X
X
X
X X X X X X X X X X X X X X X X X X X

Terminals 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
4 4
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

, Test - Bypass Equipped
+ The Cat. Number is out of date & will be removed the following
year to allow stock out.

n The panel requires a HP40TFKIT kit to be purchased if this panel is to be
served from overhead.
"" New addition to the book.

-I
C
C")
i iUI
0
i"ti
...

! i)- = nMP'PI

-=1=... !E;= m
en

..... :...z..

~
n
0

.-..I..
~

3: m

3: 0

-O
.... n 0 I

0

0 0\

9 m
"Tl
"mTl

m en
~

~
.~....

n en

<

0 3:

8
:z

m 3: :z

0
~

0

m

.... .... .... .SI, .SI,

I

I

00 00 0\

-a u,
ID :;:a
. I
°'0 U.,:aI.
-II N
....,:a.

USE: Reference list to purchase or stock approved metering service equipment

TEP SR# SR-412 SR-412 SR-412 SR-412 SR-412 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-412 SR-410 SR-410 SR-410 SR-410 SR-410

Type of Application All-In-One All-In-One All-In-One
Commercial Meter Main Combo All-In-One
Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial All-In-One Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo

APPROVED METERING AND SERVICE EQUIPMENT

Size

Manufacturer

400

Siemens

400

Siemens

400

Siemens

400

Siemens

400

Square D

100

Milbank

100

Milbank

100

Murray

100

Murray

100

Murray

100

Murray

100

Siemens

200

Milbank

200

Milbank

200

Murray

200

Murray

200

Murray

200

Siemens

200

Siemens

200

Talon

200

Talon

320

Murray

320

Murray

320

Siemens

320

Siemens

400

Siemens

400

Siemens

400

Siemens

100

Cooper B-Line

100

Cooper B-Line

100

Cooper B-Line

100

Milbank

100

Milbank

Catalog Number MC3042S1400FC MC3042S1400SD MC3042S1400FD MM0404L1400SCS , SU3040D400CN
U214MTBL U217MTBL MM0202F1100CEY , MM0202L1100EY , MM0303F3100CEY , MM0303L3100EY , MC1224B1100CESS , U224MTBL U227MTBL MM0202L1200CEY , MM0303F3200CEY , MM0303L3200CEY , MC2440B1200CEY MC2440B1200CESS , MM0202L1200CEY MM0202L1200EY BY1451GL , BY1455GL , MC3040MB21SS , MC3040MB22SS , MC0816B1400SCS , MC3042B1400SCS , MC3042B1400SC U214MTB U215MTB U217MTB U214MTB U214MTB-48

Phase 1 1 1 1 1 1 3 1 1 3 3 1 1 3 1 3 1 1 1 1 1 1 1 1 1 1 1 1 1 3 3 1 1

Fault Rating 22 22 22 22 25 10 10 100 65 100 65
10 to 65 10 10 35 100 35
10 to 22 10 to 65
35 35 22 22 22 22 22 22 22 10 10 10 10 14

OH UG X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

Terminals 4 4 4 4 4 4 7 4 4 7 7 4 4 7 4 7 7 4 4 4 4 4 4 4 4 4 4 4 4 5 7 4 4

, Test - Bypass Equipped
+ The Cat. Number is out of date & will be removed the following
year to allow stock out.

n The panel requires a HP40TFKIT kit to be purchased if this panel is to be
served from overhead.
"" New addition to the book.

-I
C
C")
i iUI
0
i"ti
...

! i)- = nMP'PI

-=1=... !E;= m
en

..... :...z..

~
n
0

.-..I..
~

3: m

3: 0

-O
.... n .SI,

I

0

0

9 m
"Tl
"mTl

m en
~

~
.~....

n en

<

0 3:

8
:z

m 3: :z

0
~

0

m

.... .... .... .SI, .SI,

I

I

UI 00 00

.-a u,
ID :;:a I
""J .,:a.
...0 UI
.... N
.,:a.

USE: Reference list to purchase or stock approved metering service equipment

TEP SR# SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-412 SR-418 SR-410 SR-410 SR-410 SR-408 SR-408 SR-408 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-408 SR-408 SR-408 SR-410

Type of Application Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo Commercial Meter Main Combo
Commercial Meter Pak Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only

APPROVED METERING AND SERVICE EQUIPMENT

Size

Manufacturer

100

Milbank

100

Milbank

100

Siemens

100

Siemens

200

Cooper B-Line

200

Cooper B-Line

200

Cooper B-Line

200

Milbank

200

Milbank

200

Milbank

200

Milbank

200

Siemens

200

Siemens

200

Square D

200

Square D

400

Siemens

200

Myers/Ryea

100

Cooper B-Line

100

Cooper B-Line

100

Cooper B-Line

100

Murray

100

Murray

100

Murray

100

Siemens

100

Siemens

100

Siemens

200

Cooper B-Line

200

Cooper B-Line

200

Cooper B-Line

200

Murray

200

Murray

200

Murray

200

Siemens

Catalog Number U217MTB
U217MTB-48 MM0202L1100ESS ¥ MM0202L3100ESS ¥
U224MTB U225MTB U227MTB U224MTB U224MTB-48 U227MTB U227MTB-48 MM0202L1200CESS ¥ MM0202L3200CESS ¥ EMT1225CB EMT3225CB MM0404L1400SCS ¥ WSM12-3
114TB 115TB 117TB MS14TB ¥ MSlSTB ¥ MS17TB ¥ MS14TB ¥ MSlSTB ¥ MS17TB ¥ 124TB 125TB 127TB MS24TB ¥ MS25TB ¥ MS27TB ¥ MS24TB ¥

Phase 3 3 1 3 1 3 3 1 1 3 3 1 3 1 1 1 3 1 3 3 1 3 3 1 3 3 1 3 3 1 3 3 1

Fault Rating 10 14
10 to 100 10 to 100
10 10 10 10 14 10 14 10 to 100 10 to 100 100 100 22 65 100 100 100 100 100 100 10 to 100 10 to 100 10 to 100 22 22 22 100 100 100 10 to 100

OH UG X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X X

Terminals 7 7 4 7 4 5 7 4 4 7 7 4 7 5 7 4 7 4 5 7 4 5 7 4 5 7 4 5 7 4 5 7 4

, Test - Bypass Equipped
+ The Cat. Number is out of date & will be removed the following
year to allow stock out.

n The panel requires a HP40TFKIT kit to be purchased if this panel is to be
served from overhead.
"" New addition to the book.

-I
C
C")
i iUI
0
i"ti
...

! i)- = nMP'PI

-=1=... !E;= m
en

..... :...z..

~
n
0

.-..I..
~

3: m

3: 0

-O
.... n .SI,

I

0

0

9 m
"Tl
"mTl

m en
~

~
.~....

n en

<

0 3:

8
:z

m 3: :z

0
~

0

m

.....SI, I

.....SI, I

....
en

00 00

.-a u,

ID :;:a

co

I
.,:a.

...0 UI
-II N
.,:a.

USE: Reference list to purchase or stock approved metering service equipment

TEP SR# SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-410 SR-418 SR-418 SR-418 SR-418 SR-418 SR-418 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409

Type of Application Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only Commercial Meter Socket Only
Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal

APPROVED METERING AND SERVICE EQUIPMENT

Size

Manufacturer

200

Siemens

200

Siemens

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200 Eaton Cutler-Hammer

200

Square D

200

Square D

200

Square D

200

Square D

200

Square D

200

Square D

100

Cooper B-Line

100

Cooper B-Line

100

Cooper B-Line

100

Cooper B-Line

100

Emerson

100

Emerson

100

Milbank

100

Milbank

100

Milbank

100

Milbank

100

Milbank

100

Myers/Ryco

100

Myers/Ryco

Catalog Number MS25TB , MS27TB ,
35SS120RAB , 35SS120RAC , 35SS120RBC , 35SS220RAB , 35SS220RAC , 35SS220RBC , 35SS320RAB , 35SS320RAC , 35SS320RBC ,
37SS120R , 37SS220R , 37SS320R , EZMT111225 EZMT112225 EZMT311225 EZMT312225 EZMT331225 EZMT332225 CMP4111MC-1 CMP4111MCH-1 CMP4411MC-1 CMP4411MCH-1 4PE24MEBBRRY3MEZ1 4PE24MEBDERY3MEZ1 CP3B11115A22 CP3B11119A22 CP3B11119B22 CP3B115l3A22 CP3B13115AW MEUG16-M100 MEUG20-M100

Phase 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 3 3 3 3 1 1 3 3 1 1 1 1 1 3 1 1 1

Fault Rating 10 to 100 10 to 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 10 10 10 10 42 42 22 22 22 22 10 10 10

OH UG X X X X
X X X X X X X X X X X X X

Terminals 5 7 5 5 5 5 5 5 5 5 5 7 7 7 4 4 5 5 7 7 4 4 7 7 4 4 4 4 4 7 4 4 4

, Test - Bypass Equipped
+ The Cat. Number is out of date & will be removed the following
year to allow stock out.

n The panel requires a HP40TFKIT kit to be purchased if this panel is to be
served from overhead.
"" New addition to the book.

-I
C
C")
i iUI
0
i"ti
...

! i)- = nMP'PI

-=1=... !E;= m
en

..... :...z..

~
n
0

.-..I..
~

3: m

3: 0

-O
.... n .SI,

I

0

0

9 m
"Tl
"mTl

m en
~

~
.~....

n en

<

0 3:

8
:z

m 3: :z

0
~

0

m

.....SI, I

.....SI, I

....
en

00 00

.-a u,
ID :;:a I
U) .,:a.
...0 UI
-II N
.,:a.

USE: Reference list to purchase or stock approved metering service equipment

TEP SR# SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409

Type of Application
Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal

APPROVED METERING AND SERVICE EQUIPMENT

Size

Manufacturer

Catalog Number

Phase

100

Myers/Ryea

MEUG24-PB-M100

1

100

Myers/Ryea

MEUG26-060-CTV

1

100

Myers/Ryea

MEUG35-PB-M100

1

100

Myers/Ryea

MEUG35-UPS-M100

1

100

Myers/Ryea

MEUG46-M100

1

100 Pacific Utility Products USP16-M2100-112CTB-TUC

1

100

Strong Box

CSP-116-lOK

1

100

TESCO

11-000

1

100

TESCO

11-000

1 or 3

100

TESCO

24-200

1

100

TESCO

26-000

1

100

TESCO

26-000

1 or 3

100

TESCO

26-100

1

100

TESCO

26-100

1 or 3

100

TESCO

27-000

1

100

TESCO

27-100

1

100

TESCO

28-102

1

100

TESCO

28-105

1

125

ALPHA

UPE-M3

1

125

ALPHA

UPE-M6

1

125

ALPHA

UPE-M8

1

125

Milbank

CP3B13115A22

1

125

Myers/Ryea

MEUG16-M125-B2448-AZ

1

125

Myers/Ryea

MEUG16-M200

1

200

Cooper B-Line

CMP4121MC-1

1

200

Cooper B-Line

CMP4121MCH-1

1

200

Cooper B-Line

CMP4421MC-1

3

200

Cooper B-Line

CMP4421MCH-1

3

200

Milbank

CP3B12115A22

1

200

Milbank

CP3B12119A22

1

200

Milbank

CP3B12513A22

3

200

Myers/Ryea

MEUG16-Ml25

1

200

Myers/Ryea

MEUG16-M200-1220

3

200

Myers/Ryea

MEUG16-M200-B2748

3

200

Myers/Ryea

MEUG20-M200

1

Fault Rating 10 22 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 22 14 10 10 10 10 10 22 22 22 10 42 35 10

OH UG X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
X X X X X

Terminals 4 4 4 4 4 4 4 4 5 4 4 5 4 5 4 4 4 4 4 4 4 4 4 4 4 4 7 7 4 4 7 4 7 7 4

, Test - Bypass Equipped
+ The Cat. Number is out of date & will be removed the following
year to allow stock out.

n The panel requires a HP40TFKIT kit to be purchased if this panel is to be
served from overhead.
"" New addition to the book.

-I
C
C")
i iUI
0
i"ti
...

! i)- = nMP'PI

-=1=... !E;= m
en

..... :...z..

~
n
0

.-..I..
~

3: m

3: 0

-O
.... n .SI,

I

0

0

9 m
"Tl
"mTl

m en
~

~
.~....

n en

<

0 3:

8
:z

m 3: :z

0
~

0

m

.....SI, I

.....SI, I

....
en

00 00

....-a u,
I? :;:a
.... .,:Ia.
o UI
g_ N
.,1:11,

USE: Reference list to purchase or stock approved metering service equipment

TEP SR# SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-409 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408 SR-408

Type of Application
Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Commercial Pedestal Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo Meter Main Combo

APPROVED METERING AND SERVICE EQUIPMENT

Size

Manufacturer

200

Myers/Ryea

200

Myers/Ryea

200

Myers/Ryea

200

TESCO

200

TESCO

200

TESCO

200

TESCO

200

TESCO

200

TESCO

200

TESCO

200

TESCO

200

TESCO

200

TESCO

100

Cooper B-Line

100

Cooper B-Line

100

Cooper B-Line

100

Cooper B-Line

100

Cooper B-Line

100

Cooper B-Line

100

Milbank

100

Milbank

100

Siemens

125 Eaton Cutler-Hammer

125 Eaton Cutler-Hammer

125 Eaton Cutler-Hammer

125 Eaton Cutler-Hammer

125

GE

125

Siemens

125

Siemens

125

Siemens

125

Siemens

125

Square D

150

Siemens

200

Cooper B-Line

200

Cooper B-Line

Catalog Number MEUG35-UPS-M200
MEUG46-M200 MEUG46-M200-2748
24-102 24-200 24-200 27-000 27-000 27-100 27-100 28-102 28-105 28-105 1M1R 1M1RF 1M1RP 1M1RPF U1M1R U1M1RF U3424-RL-100 U3564-0-100 MM0202B1100ESC CMBE24L125BTF CMBE24L125BTS MBE24L125BTF MBE24L125BTS TSL412CSCU MM0202L1125EFC MM0202L1125ESC MM0406L1125FEC MM0406L1125SEC SC8L125S MM0202B1150 2M25R 2M25RF

Phase 1 1 3
1 or 3 3
1 or 3 3
1 or 3 3
1 or 3 3 3
1 or 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Fault Rating 10 10 14 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 22
10/22 10/22
10 10 22 22 22 22 22 10 22 10 10

OH UG X X X X X X X X X X X X X
X X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

Terminals 4 4 7 5 7 5 7 5 7 5 7 7 5 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

, Test - Bypass Equipped
+ The Cat. Number is out of date & will be removed the following
year to allow stock out.

n The panel requires a HP40TFKIT kit to be purchased if this panel is to be
served from overhead.
"" New addition to the book.

Preparing to load PDF file. please wait...

0 of 0
100%