(VI) Telephone function (optional) When the machine is turned on, the icon will flicker on the panel if there is an incoming call; meanwhile, the speaker will play the ring tone. Touch the button on the touch panel to answer the call, and the icon will stop flickering. Touch the button on the touch panel again to end the call.

(VII) Failure Alarm Code This machine has autonomous failure detection function. When the failure is detected, the corresponding failure code will be displayed on the screen as

Failure Code

Failure Description

Communication failure of steamer

E1

cables

Countermeasure
Inspect whether poor contact of the steamer Cables occurs

E2

Inlet valve failure

Inspect the inlet valve and the connecting wires.

E3

Drain valve failure

Inspect the drain valve and the connecting wires.

Failure of water inlet or drainage of

E4

steamer

Insect the driving chip of the water inlet or drainage valve.

E5

Water inlet failure of steamer

Inspect whether water failure occurs.

E6

Temperature probe failure

Inspect whether the probe wires are damaged or poorlycontacted.

IV. Technical Parameters
Operation Conditions and Characteristics

Rated voltage Rated current
Insulated resistor

AC 220V 13.8A >20M

Waterproof level

IPX5

Rated frequency Rated power Current leakage Current leakage protection

50Hz-60Hz
3050W
As per the enterprise product inspection standard (15-30)mA

Load type
Steam Ceiling lamp Background lamp Ozone disinfection Fan Electromagnetic valveNote1 Speaker

Load Configuration Parameters

Rated load voltage Rated load frequency Rated load power

Ac 220V Ac 12V Ac 12V Ac 12V Dc 12V

50Hz/60Hz 50Hz/60Hz 50Hz/60Hz 50Hz/60Hz
-----

3kW 25W 5W 5W 3W

Dc 12V

-----

5W

-----

-----

8/ 1 0W

QTY 1 1 1 1 1
2
1

Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

STEAM BATHROOM
MODEL : WS-803L
Sanitary Ware Expert, Your best choice!

TECHNIQUE PARAMETER

Voltage

Frequency Water Volatge Power of steam generator

AC220V(±10%)

50/60HZ

0.1~0.2Mpa

3KW

CONSTRUCTION SKETCH

Handrail

Glass door

Moveable shower

SIZE:1380X880X2150mm
01

(II) Alarm function

when the machine is turned on , touch the button

3seconds on the panel to turn

on alarm function, the screen showing

,meanwhile ,turn off steam function

and radio function , and turn on fan function and lamp function .The speaker will be

sound the alarm .After touch the button

turn off the alarm will relief the alarm.

(II) Lamp function When the machine is turned on, touch the button the ceiling lamp.

on the touch panel to turn on/off

(III) Fan function When the machine is turned on, touch the button on the touch panel to turn on/off the fan. When the fan is turned on, the fan indicate will illuminate simultaneously.

(IV) Radio function

1、 When the machine is turned on, touch the button on the touch panel to turn

on/off the radio function. When the radio function is turned on, the radio frequency

will be displayed on the screen, such as

.

2、 Touch the button on the touch panel to go to the frequency tuning mode, and

the icon will flicker on the screen. Press the button or to tune the radio

frequency. Touch and hold the button to store the current frequency, and the

currently stored frequency channel will be displayed on the screen, such as

.

3、 When the radio is turned on, touch the button to swap the frequency channels, and the range of frequency channels is from 1 to 8.

4、Under the radio status, touch the button on the touch panel to go to the volume

adjustment mode, and the range of adjustment is from 1 to 15, and the volume will be

displayed on the screen during adjustment, such as

.

(V) Steam function 1、 When the machine is turned on, touch the button on the touch panel to turn on/off the steam function. When the steam function is started, the steam function indicator will illuminate. After the steam function is enabled, the default set time for steam is 45 minutes, and the default temperature is 100F.

2、When the steam function is started, touch the button on the touch panel to go

to the steam setting mode. If the icon flickers on the screen, such as , it enters

the steam time setting status, and the number displayed is the remaining time for

steam operation. Touch the button again to swap to the steam temperature setting

status, and the icon flickers on the screen, such as

, and the number displayed

is the steam temperature setting value.

10 WS-803L

I. Instructions
1. Capacitor touch buttons are adopted in this panel. In selecting the position to install the panel, we should avoid facing directly the spray and shower nozzle, otherwise it may lead to mistaken operation of the panel or locking the panel; 2. The location area of each function button on the panel is the optimum touch
range; 3. The panel is optimized with waterproof function. When mistaken operation is tested (with two or more keys touched simultaneously), there will be no response. Wait for about 1 second to restore operation. 4. Under the status of panel locking, the system gives no response when touching the panel, and the icon flickers on the LCD. At this time, touch the key for two seconds, and the locking will be released. Meanwhile, the icon goes off on the LCD, and you can operate the keys on the panel. 5. When touching any key on the panel, the operating system will give a “beep” tone if the system operation is enabled.

II. Introduction to Functions
1.Lamp function; 2.Fan function;

3.Steam function;

4.Radio function 5.Telephone function; 6.Failure code indication;

7.Ozone disinfection after turning off; 8.Alarm function

III. Method of Operation
(I) Turn on/off the machine
1. Standby mode The system is in standby mode after power on, and a red dot will be displayed on the screen to indicate connected power.
2. Turn on the machine When the system is in standby mode, touch and hold the button for two seconds to start the machine and the current temperature will be displayed on the screen, such as
. At the same time, the ceiling lamp will light up. When the machine is started, it is timed for 60 minutes and the machine will shut off automatically when the time is due.
3. Turn off the machine Either the button on the touch panel is touched or the default set time (60 minutes) is up, the machine will be turned off, and all the activated functions will be disenabled, and the system will go back to the standby mode. After the system is turned off for 30 seconds, the automatic water discharge function will be started automatically.
09

CONSTRUCTION SKETCH 1

2

10

3

11

12 4
13 5

6

15

14

7

16

17 8 18

9 19

1、top light 2、speaker 3、top shower 4、room body 5、moveable shower 6、control panel 7、towel shelf

8、seat 9、drainage 10、exhaust fan 11、ozone 12、decorated light 13、mirror 14、shift switch

15、back light 16、cold/hot water switch 17、nozzle 18、steam out 19、bottom tray
02 WS-803L

INSTALLATION SKETCH

1250

The socket

150

of power and

the socket

of telephone

Cold water pipe Hot water pipe

1800

200 690
Other screws M4x15 M4x25 ST5x25
Install the screw M6x25
Active chain wheel of glass
SIZE:1380X880X2150mm ILLUSTRATION OF INSTALLATION 1.The products should be installed by technical guy who are got
the certificate or those technical who are assign by dealers. The main power switch and electronic leakage device should be installed. 2.The plug of electronic should be installed above the steam generator and the length of electronic wire not less then 1800MM from the earth. 3.There are should be with main power switch for hot and cold water pipe of steam room and the water pipe should be connect to drainage water pipe. 4.Install the products according to the diagram of installation When fixed the place for the products.
03

E

A

S

B

1、On/Off function key 2、Fan function key 3、Steam adjustment function key 4、Radio/Telephone receive function key 5、Parameter setting decrease key A、Fan function indicator

6、Lamp/Alarm function key 7、Steam function key 8、Radio tuning function key 9、Radio memory key 10、Parameter setting increase key B、Steam function indicator
08 WS-803L

DRAWING OF WATER CONNECTION
As the“ ”from the picture,please make the connection according to the serial number v1,v2,etc.
Top shower

Nozzle
Hot water connection (red pipe)

Movable shower head
Nozzle

Movable shower head
Cold water connection (blue pipe)

Steam generator

ELECTRIC CIRCUIT SKETCH
Back light

Antenna

Exhaust fan

Roof lamp Speaker

Ozone

CD Pc control
Telephone

Temperature needle

Electric box

Power

Dark red (live)
Blue (neutral)
Twin Line (ground)

Steam generator

Please install the earth line safely

by professional technician.

07

Earth line

INSTALLATION PROCESS STEP 1
St5x25

STEP 2
Chain wheel of glass door

STEP 3

04 WS-803L

Plastic pad

STEP 4
M4×15
STEP 5
05

STEP 6

STEP 7

WS-803L 06